Ethernet Cable Cat.7A S/FTP LSZH – 23AWG
€713,00 €876,99 Incl. VAT
barpa Cat.7A S/FTP installation cable: foil-screened pairs under an overall braid, 23 AWG copper conductors and an LSZH jacket. Specified to 1000 MHz, tested to 1200 MHz, for Class FA links including 10GBASE-T.
Cat.7A is an ISO/IEC category (Class FA, 1000 MHz), and Class FA needs GG45 or TERA connectors. Terminated on RJ45 jacks and patch panels, which is how almost every Cat.7A cable is installed, the link performs as the RJ45 hardware allows: Cat.6A, Class EA. What you get over a Cat.6A cable is the shielding and the extra headroom in the cable itself, not more speed. With 23 AWG conductors and a 7.8 ± 0.5 mm jacket it is within the range of the barpa shielded Cat.6A keystone, which takes 22-26 AWG conductors and 5.0-8.5 mm cable.
It supports PoE, PoE+, PoE++ and 4PPoE, and the jacket has descending metre marking. CPR class Cca-s1a,d1,a1. Sold as a full 500 m reel or cut to the length you need.
| Category | Cat.7A S/FTP |
|---|---|
| Max. frequency | 1000 MHz (tested to 1200 MHz) |
| Applications | Class FA, 10GBASE-T |
| CPR class | Cca-s1a,d1,a1 |
| Use | Indoor |
| Available lengths | 500 m (reel), 100 m, 50 m, 20 m, per metre |
| Conductor | Copper, 23 AWG, 0.56 ± 0.005 mm |
|---|---|
| Insulation | Skin-foam-skin PE, 1.33 ± 0.05 mm |
| Shielding | Aluminium foil on each pair, overall metal braid, drain wire |
| Jacket | LSZH, 0.55 mm thick |
| Outer diameter | 7.8 ± 0.5 mm |
| Jacket colour | Orange (RAL 2003) |
| Rip cord | Yes |
| Metre marking | Descending |
| Impedance | 100 ± 15 Ω (1-100 MHz), 100 ± 18 Ω (100-250 MHz), 100 ± 25 Ω (250-1000 MHz) |
|---|---|
| DC resistance | 7.2 Ω/100 m |
| NVP | 74% |
| Delay skew | 12 ns/100 m |
| PoE | IEEE 802.3bt Type 1, 2, 3 and 4 |
| Operating temperature | -20 to 75 °C |
|---|---|
| Installation temperature | 0 to 50 °C |
| Min. bend radius (operation) | 4 x cable diameter |
| Max. pulling tension | 100 N |
| Electrical performance | ISO/IEC 11801, IEC 61156-5, EN 50173, EN 50288-9-1, ANSI/TIA-568-D |
|---|---|
| Fire behaviour | IEC 60332-3-24, IEC 60754, IEC 61034, EN 50267-2-3, EN 13501-6, EN ISO 1716:2010, EN 50575 |
barpa Cat.7A S/FTP installation cable: foil-screened pairs under an overall braid, 23 AWG copper conductors and an LSZH jacket. Specified to 1000 MHz, tested to 1200 MHz, for Class FA links including 10GBASE-T.
Cat.7A is an ISO/IEC category (Class FA, 1000 MHz), and Class FA needs GG45 or TERA connectors. Terminated on RJ45 jacks and patch panels, which is how almost every Cat.7A cable is installed, the link performs as the RJ45 hardware allows: Cat.6A, Class EA. What you get over a Cat.6A cable is the shielding and the extra headroom in the cable itself, not more speed. With 23 AWG conductors and a 7.8 ± 0.5 mm jacket it is within the range of the barpa shielded Cat.6A keystone, which takes 22-26 AWG conductors and 5.0-8.5 mm cable.
It supports PoE, PoE+, PoE++ and 4PPoE, and the jacket has descending metre marking. CPR class Cca-s1a,d1,a1. Sold as a full 500 m reel or cut to the length you need.
| Category | Cat.7A S/FTP |
|---|---|
| Max. frequency | 1000 MHz (tested to 1200 MHz) |
| Applications | Class FA, 10GBASE-T |
| CPR class | Cca-s1a,d1,a1 |
| Use | Indoor |
| Available lengths | 500 m (reel), 100 m, 50 m, 20 m, per metre |
| Conductor | Copper, 23 AWG, 0.56 ± 0.005 mm |
|---|---|
| Insulation | Skin-foam-skin PE, 1.33 ± 0.05 mm |
| Shielding | Aluminium foil on each pair, overall metal braid, drain wire |
| Jacket | LSZH, 0.55 mm thick |
| Outer diameter | 7.8 ± 0.5 mm |
| Jacket colour | Orange (RAL 2003) |
| Rip cord | Yes |
| Metre marking | Descending |
| Impedance | 100 ± 15 Ω (1-100 MHz), 100 ± 18 Ω (100-250 MHz), 100 ± 25 Ω (250-1000 MHz) |
|---|---|
| DC resistance | 7.2 Ω/100 m |
| NVP | 74% |
| Delay skew | 12 ns/100 m |
| PoE | IEEE 802.3bt Type 1, 2, 3 and 4 |
| Operating temperature | -20 to 75 °C |
|---|---|
| Installation temperature | 0 to 50 °C |
| Min. bend radius (operation) | 4 x cable diameter |
| Max. pulling tension | 100 N |
| Electrical performance | ISO/IEC 11801, IEC 61156-5, EN 50173, EN 50288-9-1, ANSI/TIA-568-D |
|---|---|
| Fire behaviour | IEC 60332-3-24, IEC 60754, IEC 61034, EN 50267-2-3, EN 13501-6, EN ISO 1716:2010, EN 50575 |