Product form

Ethernet Cable Cat.7 S/FTP LSZH – 23AWG

€416,00 €511,68 Incl. VAT

barpa Cat.7 S/FTP installation cable: foil-screened pairs under an overall braid, 23 AWG copper conductors and an LSZH jacket. Specified... Read more Read more

SKU: 82224421030C1
Barcode: 5608445014481


Available · ships in 2–4 working days


    barpa Cat.7 S/FTP installation cable: foil-screened pairs under an overall braid, 23 AWG copper conductors and an LSZH jacket. Specified to 600 MHz, tested to 1000 MHz, for Class F links including 10GBASE-T.

    Cat.7 is an ISO/IEC category (Class F, 600 MHz), and Class F needs GG45 or TERA connectors. Terminated on RJ45 jacks and patch panels, which is how almost every Cat.7 cable is installed, the link performs as the RJ45 hardware allows: Cat.6A, Class EA. What you get over a Cat.6A cable is the shielding and the extra headroom in the cable itself, not more speed. With 23 AWG conductors and a 7.8 ± 0.5 mm jacket it is within the range of the barpa shielded Cat.6A keystone, which takes 22-26 AWG conductors and 5.0-8.5 mm cable.

    It supports PoE, PoE+, PoE++ and 4PPoE, and the jacket has descending metre marking. CPR class Cca-s1a,d1,a1. Sold as a full 305 m reel or cut to the length you need.

    Key features

    • Category 7 S/FTP, 600 MHz (tested to 1000 MHz)
    • Class F, 10GBASE-T
    • Foil on each pair plus overall braid and drain wire
    • 23 AWG copper conductors, 0.56 mm
    • LSZH jacket, 7.8 mm, orange (RAL 2003)
    • CPR class Cca-s1a,d1,a1
    • PoE to IEEE 802.3bt Type 1, 2, 3 and 4

    Description

    barpa Cat.7 S/FTP installation cable: foil-screened pairs under an overall braid, 23 AWG copper conductors and an LSZH jacket. Specified to 600 MHz, tested to 1000 MHz, for Class F links including 10GBASE-T.

    Cat.7 is an ISO/IEC category (Class F, 600 MHz), and Class F needs GG45 or TERA connectors. Terminated on RJ45 jacks and patch panels, which is how almost every Cat.7 cable is installed, the link performs as the RJ45 hardware allows: Cat.6A, Class EA. What you get over a Cat.6A cable is the shielding and the extra headroom in the cable itself, not more speed. With 23 AWG conductors and a 7.8 ± 0.5 mm jacket it is within the range of the barpa shielded Cat.6A keystone, which takes 22-26 AWG conductors and 5.0-8.5 mm cable.

    It supports PoE, PoE+, PoE++ and 4PPoE, and the jacket has descending metre marking. CPR class Cca-s1a,d1,a1. Sold as a full 305 m reel or cut to the length you need.

    Key features

    • Category 7 S/FTP, 600 MHz (tested to 1000 MHz)
    • Class F, 10GBASE-T
    • Foil on each pair plus overall braid and drain wire
    • 23 AWG copper conductors, 0.56 mm
    • LSZH jacket, 7.8 mm, orange (RAL 2003)
    • CPR class Cca-s1a,d1,a1
    • PoE to IEEE 802.3bt Type 1, 2, 3 and 4

    Specifications

    General

    Category Cat.7 S/FTP
    Max. frequency 600 MHz (tested to 1000 MHz)
    Applications Class F, 10GBASE-T
    CPR class Cca-s1a,d1,a1
    Use Indoor
    Available lengths 305 m (reel), 100 m, 50 m, 20 m, per metre

    Construction

    Conductor Copper, 23 AWG, 0.56 ± 0.005 mm
    Insulation Skin-foam-skin PE, 1.33 ± 0.05 mm
    Shielding Aluminium foil on each pair, overall metal braid, drain wire
    Jacket LSZH, 0.55 mm thick
    Outer diameter 7.8 ± 0.5 mm
    Jacket colour Orange (RAL 2003)
    Rip cord Yes
    Metre marking Descending

    Electrical (20 °C)

    Impedance 100 ± 15 Ω (1-100 MHz), 100 ± 18 Ω (100-250 MHz), 100 ± 25 Ω (250-600 MHz)
    DC resistance 7.2 Ω/100 m
    NVP 74%
    Delay skew 12 ns/100 m
    PoE IEEE 802.3bt Type 1, 2, 3 and 4

    Installation

    Operating temperature -20 to 75 °C
    Installation temperature 0 to 50 °C
    Min. bend radius (operation) 4 x cable diameter
    Max. pulling tension 100 N

    Standards

    Electrical performance ISO/IEC 11801, IEC 61156-5, EN 50173, EN 50288-4-1, ANSI/TIA-568-D
    Fire behaviour IEC 60332-3-22, IEC 60754, IEC 61034, EN 50267-2-3, EN 13501-6, EN ISO 1716:2010, EN 50575

    Datasheet (PDF)