Ethernet Cable Cat.6A U/UTP PE (Exterior) – 23AWG
€525,00 €645,75 Incl. VAT
barpa Cat.6A U/UTP outdoor cable with 23 AWG solid copper and a black UV-resistant PE jacket, specified to 500 MHz for Class EA links including 10GBASE-T.
It is made for outdoor runs and works from -20 to 75 °C. The pairs are unshielded and kept apart by a cross separator, and the jacket has descending metre marking. The CPR class is Fca. Sold as a full 500 m reel or cut to the length you need.
| Category | Cat.6A U/UTP |
|---|---|
| Max. frequency | 500 MHz |
| Applications | Class EA, 10GBASE-T |
| CPR class | Fca |
| Use | Outdoor |
| Available lengths | 500 m (reel), 100 m, 50 m, 20 m, per metre |
| Weight | 22 kg per 500 m reel (net) |
| Conductor | Solid copper, 23 AWG, 0.565 ± 0.005 mm |
|---|---|
| Insulation | HDPE, 1.02 ± 0.03 mm |
| Pair separator | Cross separator |
| Shielding | None (U/UTP) |
| Jacket | PE, UV resistant, halogen-free, 0.60 ± 0.05 mm thick |
| Outer diameter | 6.9 ± 0.5 mm |
| Jacket colour | Black (RAL 9005) |
| Rip cord | Yes |
| Metre marking | Descending |
| Impedance | 100 ± 15 Ω |
|---|---|
| DC resistance | 7.4 Ω/100 m |
| NVP | 69% |
| Delay skew | 35 ns/100 m |
| PoE | IEEE 802.3bt Type 1, 2, 3 and 4 |
| Operating temperature | -20 to 75 °C |
|---|---|
| Installation temperature | 0 to 50 °C |
| Min. bend radius (operation) | 4 x cable diameter |
| Max. pulling tension | 100 N |
| Electrical performance | ISO/IEC 11801, IEC 61156-5, EN 50173, EN 50288-11-1, ANSI/TIA-568-D |
|---|---|
| Reaction to fire (CPR) | EN 50575:2014+A1:2016, class Fca |
barpa Cat.6A U/UTP outdoor cable with 23 AWG solid copper and a black UV-resistant PE jacket, specified to 500 MHz for Class EA links including 10GBASE-T.
It is made for outdoor runs and works from -20 to 75 °C. The pairs are unshielded and kept apart by a cross separator, and the jacket has descending metre marking. The CPR class is Fca. Sold as a full 500 m reel or cut to the length you need.
| Category | Cat.6A U/UTP |
|---|---|
| Max. frequency | 500 MHz |
| Applications | Class EA, 10GBASE-T |
| CPR class | Fca |
| Use | Outdoor |
| Available lengths | 500 m (reel), 100 m, 50 m, 20 m, per metre |
| Weight | 22 kg per 500 m reel (net) |
| Conductor | Solid copper, 23 AWG, 0.565 ± 0.005 mm |
|---|---|
| Insulation | HDPE, 1.02 ± 0.03 mm |
| Pair separator | Cross separator |
| Shielding | None (U/UTP) |
| Jacket | PE, UV resistant, halogen-free, 0.60 ± 0.05 mm thick |
| Outer diameter | 6.9 ± 0.5 mm |
| Jacket colour | Black (RAL 9005) |
| Rip cord | Yes |
| Metre marking | Descending |
| Impedance | 100 ± 15 Ω |
|---|---|
| DC resistance | 7.4 Ω/100 m |
| NVP | 69% |
| Delay skew | 35 ns/100 m |
| PoE | IEEE 802.3bt Type 1, 2, 3 and 4 |
| Operating temperature | -20 to 75 °C |
|---|---|
| Installation temperature | 0 to 50 °C |
| Min. bend radius (operation) | 4 x cable diameter |
| Max. pulling tension | 100 N |
| Electrical performance | ISO/IEC 11801, IEC 61156-5, EN 50173, EN 50288-11-1, ANSI/TIA-568-D |
|---|---|
| Reaction to fire (CPR) | EN 50575:2014+A1:2016, class Fca |